Jiangmen Jutai Pump Co., Ltd.

Miniature brushless pumps · pet-fountain integration · solar fountain kits

Jiangmen Jutai Pump Co., Ltd.

Jiangmen Jutai’s catalogue spans miniature appliance pumps and solar fountain assemblies. For an OEM project, match the exact electrical version, hydraulic circuit, mounting and control functions. For a fountain kit, define the panel, nozzles and daylight operating conditions.

Chinese company name
江门市钜泰泵业有限公司
Manufacturing locality
Hetang, Pengjiang, Jiangmen, Guangdong
Related company
Shenzhen Jutai; keep the contracting entity explicit
Selection focus
Exact part revision · supply · circuit · integration tests

Start with what your appliance or garden product actually needs

Jiangmen Jutai Pump Co., Ltd. publishes miniature water-pump products for cooling, aquariums, pet drinking fountains, humidifiers and other appliance circuits, alongside solar fountain assemblies. A catalogue category is an application direction: it does not mean the manufacturer supplies the complete air conditioner, medical device or drinking-water appliance in which a pump might be used.

An appliance developer buys a component with mechanical, electrical and control interfaces. A garden retailer may instead need a solar panel, pump and interchangeable spray heads as one packaged kit. Separate these orders before comparing photographs or prices. The output expected from a cooling loop, a drinking fountain and an ornamental spray is different.

Actual catalogue examples, with project-specific procurement inputs. These are application routes rather than interchangeable performance specifications.
Your intended productPublished Jutai exampleDefine before requesting a sample
Small water-cooling circuitAD20P / AD10 product pagesSupply, circuit restriction, priming, fittings and mounting
Pet drinking fountain or aquariumJE303E and AD102/AD106/AD107 catalogue entriesReservoir level, filtration, cleaning, outlet and exact electrical revision
Outdoor daylight spray kitAS10B1 solar fountainPanel and nozzle scope, basin size, sunlight and operation without stored energy

Keep the manufacturing and contracting identities separate

The company introduction describes Jiangmen Jutai as a subsidiary of Shenzhen Jutai, with Shenzhen handling development/sales and Jiangmen production. The published 2010 history concerns the Shenzhen business; it should not be used as the founding year of the Jiangmen legal entity. Ask which company will issue the quotation, invoice, warranty and sample documentation, and identify that same company on your purchase order.

A Jiangmen environmental approval dated 27 February 2024 names 江门市钜泰泵业有限公司 and a project at Building 17, Hetang. It covers miniature pumps, related components, solar fountains and solar lights, with proposed injection moulding, winding, SMT/reflow, potting, assembly and testing equipment. This supports a specific entity and project scope. It is not a product-safety certificate, evidence of completed commissioning, or proof of present available capacity.

The company’s published exterior photograph shows Jutai branding on Building 17. Use it to understand the stated location; agree current production responsibility and the inspection or acceptance records for your order. Neither a building photograph nor the planned project output establishes stock, a delivery date or the production rate available to a buyer.

Jutai’s published exterior photograph of Building 17. This is company imagery, not an independently witnessed factory audit.
Jutai’s published exterior photograph of Building 17. This is company imagery, not an independently witnessed factory audit.

Resolve the voltage and circuit before integrating a cooling pump

The AD20P title describes a 12 V DC brushless miniature centrifugal pump for water-cooling circulation. Its original annotated image marks 8 mm inlet/outlet connections and a 45 cm lead. A second illustration shows both submerged and external arrangements. Treat these as the depicted configuration: confirm the fitting dimensions, hose retention, lead/connector and permitted mounting of the version in the quotation.

The AD10 page illustrates why the complete suffix matters. Its title says DC12V, while a gallery nameplate reads AD10D-003A, DC5V, 300 mA, 1.5 W, Qmax 380 L/h and Hmax 1.7 m. That photographed variant is not a 12 V rating for everything sold under AD10. Request the exact order code and revision, nameplate and drawing together. Maximum flow and maximum head are different curve endpoints, not one simultaneous operating point.

For a cooling loop, provide the liquid and additives, temperature, tubing length/internal diameter, fittings and the heat-exchanger restrictions. Define required flow at the assembled circuit resistance and the supply available at the pump, including start-up conditions. Request a curve and current/power data for that exact version. For an external installation, confirm how the inlet is flooded and primed, leakage limits and any dry-running protection; an external-use diagram alone does not prove self-priming.

Original AD20P connection illustration: 8 mm ports and a 45 cm lead are shown. Confirm the exact version, fittings and electrical supply in the quotation.
Original AD20P connection illustration: 8 mm ports and a 45 cm lead are shown. Confirm the exact version, fittings and electrical supply in the quotation.
The AD10 gallery shows an AD10D-003A label rated DC5V, despite the page’s DC12V title. Compare the exact label and approved revision before selecting a supply.
The AD10 gallery shows an AD10D-003A label rated DC5V, despite the page’s DC12V title. Compare the exact label and approved revision before selecting a supply.

A miniature fountain pump must fit the reservoir and its control logic

The JE303E product page shows a compact white pump with an inlet screen and a parameter illustration labelled JT303E. The table lists 5 V, 0.2–2 W, 0.8–2 L/min flow, 0.2–0.6 m head, 82 g, a 54.4 × 40.7 × 28 mm body and a 10.4 mm outlet. These are the published table entries; the ranges do not form one guaranteed duty point.

The same illustration includes a JT303E-labelled drawing with a 3.0 W marking and a 30 mm dimension, whereas its table/body illustration gives a 28 mm height. It also shows low-water sensing and red/blue operating indications. Reconcile JE303E versus JT303E, power, body versus fitting height and the included controls on a signed drawing before selecting a cavity or power supply. Do not assume every visually similar white pump includes those functions.

Provide a reservoir section drawing, minimum water level, required delivery, outlet connection and the screen/filter arrangement. Check access for removing hair or deposits, the permitted cleaning method, wet materials and the complete appliance’s intended market. Noise acceptance needs a stated mounting, water level and measurement method; a “quiet” title is not a sound-pressure test result.

The product artwork also advertises a UVC option. If you need that variant, define the optical enclosure, exposure protection, control sequence and the evidence for any treatment claim separately from pump performance. A catalogue picture cannot establish the treatment effectiveness or safety of your finished drinking fountain.

Transcribed from the illustration linked to the JE303E page. Resolve the page/table naming and drawing discrepancies before ordering.
Published JT303E table entryShown valueSample/drawing acceptance question
Electrical input5 V; 0.2–2 W in the tableWhich exact suffix and power rating apply? The accompanying label shows 3.0 W.
Hydraulic range0.8–2 L/min; 0.2–0.6 m headWhat curve and duty apply with your filter and nozzle?
Body and outlet54.4 × 40.7 × 28 mm; Ø10.4 mm outletWhich dimensions include fittings/sensor? Drawing also shows 30 mm.
Table mass82 gDoes quoted mass include the lead, screen and controls?
Original JT303E parameter artwork on the JE303E page. The table and accompanying drawing differ in power and height; resolve both against the ordered version.
Original JT303E parameter artwork on the JE303E page. The table and accompanying drawing differ in power and height; resolve both against the ordered version.

Size the basin for the spray, and plan for changes in sunlight

The AS10B1 listing describes a solar fountain approximately 17 cm in diameter, with interchangeable spray heads and a stated spray height of about 38.1–68.6 cm (15–27 inches). It describes operation in sunshine without stored energy, stopping at night. The listed spray range is not a constant all-weather duty or a water-circulation rating for a pond.

The listing describes a floating arrangement and bottom suction cups. Decide which arrangement your basin needs, how the panel receives light, and how spray is kept inside the basin when wind or sunlight changes. Ask for the actual panel/pump pairing, nozzle set and installation instructions. Do not substitute pump head for the vertical spray height of a particular nozzle.

Provide the basin diameter, water depth, intended mounting and packaging scope. The published instructions call for sufficient water, regular pump cleaning and a clean, unshaded panel. Agree the minimum water condition and the expected behaviour in partial shade. A request for battery-backed or night operation is a different configuration from this no-storage listing.

Specify the tests for the component and the complete appliance

The company describes injection moulding, PCB assembly, wire preparation, winding, product assembly and testing. For a repeat OEM order, turn these process statements into a controlled bill of materials, connector pinout, dimensional drawing and sample revision. Establish which changes require your approval, how the delivered component is identified, and which hydraulic/electrical checks accompany a lot.

Published application artwork says protections and interfaces such as reverse-polarity, overheat, overcurrent, overvoltage, low-water protection, PWM speed control and signal feedback can be provided to customer requirements. Specify the functions you need and their thresholds and behaviour, rather than assuming every standard pump includes all of them. Verify start/stop, stalled or blocked operation and the actual operating circuit in the agreed sample plan.

Jiangmen’s 2024 industrial-product surveillance list records Jiangmen Jutai’s JT400B17 permanent-magnet synchronous motor for a submersible pump, 5 W / 220 V / 50 Hz, with no nonconformity found (report DQ2402062). That is a specific inspected motor, not certification of the AD-series DC pumps, the pet-fountain controls or a finished appliance. Obtain the current documents that cover the exact component and destination-market use.

Make the quotation answer your integration problem

Use Jiangmen Jutai’s exact name in the platform enquiry and state whether you need a pump component, a controlled pump assembly or a complete solar kit. Include the existing reference and all required suffixes, and ask for a drawing, curve and sample corresponding to the same configuration. Quantities, destination and packaging should be explicit; the public catalogue does not establish MOQ, available stock or an agreed delivery schedule.

Agree sample acceptance before committing to a tooling or production order. Record the mounting envelope, connector and hose interfaces, hydraulic duty, current/power, protection behaviour, cleaning/access and any noise criterion under your actual installation conditions. Separate supplier component evidence from testing of the complete appliance.

Appliance or cooling-loop pump

  • Liquid/additives, temperature, required duty and circuit resistance; minimum/maximum supply at the pump.
  • Exact part code/revision, body/fitting drawing, lead/connector/pinout, hose retention and priming/mounting.
  • Required PWM/feedback/protection functions, noise conditions, sample acceptance and approved material scope.

Pet fountain or screened reservoir

  • Reservoir drawing, water levels, filter/screen, outlet, delivery and cleaning/removal access.
  • Resolve JE303E/JT303E naming and power/dimension conflicts with one approved drawing and sample.
  • Define included level sensor/indicator/UVC option and the complete appliance’s safety/treatment evidence.

Solar fountain kit

  • Basin width/depth, floating or fixed mounting, sunlight/shade and expected spray containment.
  • Exact AS10B1 configuration, panel/pump pairing, nozzle set, water-level instructions and kit packaging.
  • State whether daylight-only operation is acceptable; agree any alternative energy-storage configuration explicitly.
Send a project requirement

Submit through KanBeng’s enquiry form with this factory named in your request.