General water pumps · Wenling, Zhejiang
Zhejiang Dayuan Pumps Industrial Co., Ltd.
A Wenling water-pump manufacturer with distinct choices for irrigation, drainage, sewage and pressure boosting. Start with the liquid and installation, then narrow the series and duty point.
- Published Chinese company name
- 浙江大元泵业股份有限公司
- Company origin
- 1990, according to company history
- Listed company identifier
- 603757 · Shanghai Stock Exchange
- Water-pump production location
- Wenling, Zhejiang, China
- Group business distinction
- General water pumps and canned-motor pumps
Know which Dayuan business your order belongs to
Dayuan’s Chinese company profile identifies Zhejiang Dayuan Pumps Co., Ltd. (浙江大元泵业股份有限公司), with its origins in 1990 and a Shanghai listing in 2017. Its English material uses Zhejiang Dayuan Pumps Industrial Co., Ltd. and the same stock code, 603757. Match the quotation’s supplying entity, production site and product designation before agreeing the purchase order; a brand name alone is not the contracting party.
The company separates general water pumps from canned-motor pumps. General water products include small submersibles, borehole and surface pumps for agriculture, alongside inline, multistage and sewage pumps for commercial water duties. Its published base descriptions associate general water pumps with Wenling and canned-motor activities with Hefei. The Chinese profile describes the canned-motor business as operated by subsidiaries.
A February 2025 investor-relations record hosted on the statutory disclosure platform also describes these two business areas. It supports the business distinction, rather than certifying an individual pump. For a chemical circulation or liquid-cooling project, identify the relevant subsidiary and exact product documentation instead of treating a Wenling drainage pump as evidence of process-pump capability.
Different water duties need different pump designs
The examples below come from Dayuan’s own product documentation. They are starting points for a technical enquiry, rather than substitutes for selecting an exact configuration.
| Your task | Published Dayuan direction | What decides the selection |
|---|---|---|
| Clear-water drainage or farm water transfer | QDX/QX A submersibles | Liquid cleanliness, working water level, discharge head and the exact single- or three-phase version. The A design is not a sewage cutter. |
| Sewage or wastewater removal | WQ-D or the larger WQ range | Solids and fibers, required duty, immersion and installation. The small WQ-D envelope must not be applied to every WQ product. |
| Surface supply from a tank or shallow source | A1 self-priming peripheral pumps | Suction conditions, liquid temperature, priming arrangement and model-specific pressure limit. Self-priming does not mean dry-running operation. |
| Building pressure or water-treatment boosting | DV/DVL/DVS vertical multistage pumps | Flow at required pressure, inlet pressure, selected material and seal, stage count and control arrangement. |
| Canned-motor circulation or liquid cooling | Relevant Dayuan group business | Supplying subsidiary, circulating medium, thermal duty and product-specific documentation; separate from the general-water enquiry. |
Read the useful conditions behind the product names

View the reviewed product family →

View the reviewed product family →
QDX/QX A: keep clean-water and sewage enquiries separate
The Chinese QDX/QX A page describes an aluminium-shell submersible for clear water and names GB/T 25409. Its stated medium conditions include particles no larger than 0.2 mm and solids content by volume no greater than 0.1%. The practical purchasing input is the water quality as well as the duty point: describe sediment and debris before selecting a portable drainage pump. Use the complete model suffix and its rated row, rather than a range spanning several designs.
WQ-D and large WQ: a shared prefix is not a shared envelope
The English WQ-D page publishes maximum flow of 100 m³/h, maximum head of 54 m, liquid temperature up to 40 °C and immersion up to 5 m. These are separate family limits, not a guaranteed 100 m³/h at 54 m working point. The Chinese large-WQ page describes a channel impeller and names GB/T 24674; it also asks users to keep solids within the selected pump’s permitted passage. State fibers, particle size, liquid level and discharge layout so the correct WQ design can be discussed.
A1: specify the pressure class as well as the suction
A1 is described as a self-priming peripheral design for water or liquids with similar physical and chemical properties. The English page assigns different maximum working pressures to different sizes: 3 bar for A1-250 and 6 bar for A1-1100(S), with intermediate limits for other versions. This makes the complete designation important. Give source water level, pipe arrangement, demand and temperature; ask for the selected model’s curve and priming instructions before assuming the published maximum suction figure fits the installation.
DV/DVL/DVS: materials and maintenance belong in the comparison
The published vertical-multistage design uses a standard vertical motor and a quick-fit mechanical seal. Its documentation mentions 304/316 wetted materials and applications such as boosting, water treatment and cooling circulation. Specify which material schedule and seal are offered for the actual liquid. The source page gives different broad flow ranges in different sections, so this profile does not combine them into a single assured envelope. Use the exact model row, curve revision and installation drawing.
Turn published production capability into order evidence
Dayuan’s manufacturing material describes automated production lines and digitally recorded warehouse movements. For a repeat purchase, translate that into questions about drawing revision, assembly configuration, batch identity and the records supplied with shipment. An automated line by itself does not establish your delivery date or the acceptance result for your order.
The English company page lists dimensional measurement, hardness, metallographic analysis and material-analysis equipment, as well as ultrasonic inspection equipment. These capabilities are useful discussion points when alloy selection, component dimensions or casting inspection matter. Ask which checks apply to your offered pump, where they are performed and what report accompanies the batch.
For performance acceptance, agree the selected flow/head duty, test method, tolerances and reporting before purchase. If a certificate is required at the destination, obtain the current document with its holder, site and product scope. The company’s broad certification display is not a blanket approval for every pump, motor or assembled system.
Define the configuration
Freeze model suffix, electrical version, materials, seal, connection and included accessories.
Agree technical acceptance
Request the model curve and drawing; agree the duty, inspection plan and documents for the actual order.
Prepare repeat supply
Identify replaceable parts, approved revisions, package marking and the service information needed at the destination.
Use the range around your installation
A farm transfer with a submerged intake
Start with QDX/QX A when the source is sufficiently clean. Include the lowest operating level, vertical lift and pipe losses. Sediment changes the selection question; moving water from a dirty pit is not automatically the same task as irrigation from a clean reservoir.
A wastewater sump serving a building
Start with the sewage range, then describe solids, fibers, inflow pattern and the removal arrangement. Ask for the selected pump’s allowable passage, minimum liquid level and installation drawing. A cutter or guide-rail package should be specified explicitly rather than inferred from the WQ letters.
A booster or water-treatment package
Discuss DV/DVL/DVS with the required duty and inlet conditions. Put control scope, material selection and space for seal replacement in the brief. The pump, controller, tank and installation accessories need a defined supply scope if you are buying a complete package.
Prepare an enquiry the technical team can work with
Choose the applicable group below and add quantity, destination and target delivery date. Ask for a quotation covering the same configuration and acceptance requirements so alternatives can be compared fairly.
Liquid & hydraulic duty
- Liquid, temperature, sediment or solids, fibers and any corrosive constituents.
- Required flow at total head, expected operating range and lowest source level.
- For surface pumps: suction layout and priming arrangement. For submersibles: immersion and minimum operating level.
Pump & installation
- Full Dayuan designation, preferred material and seal, voltage, phase and frequency.
- Pipe size, connection, layout and limits on installation space.
- Cables, controls, level sensing, lifting or guide-rail equipment included in the order.
Supply & acceptance
- Supplying legal entity and production site; quantities and delivery destination.
- Selected model curve, dimension drawing, test requirements and any required current certificates.
- Spare-parts list, documentation language, packaging and the agreed drawing revision for repeat orders.
Submit through KanBeng’s enquiry form with this factory named in your request.
Research behind this profile
Reviewed 7 October 2026 against company identity and production material, specific product pages, and a February 2025 investor-relations disclosure. Product features and facility descriptions are company-published. The task comparisons and enquiry guidance are KanBeng’s procurement analysis. The disclosure corroborates the group’s business distinction; it does not constitute a factory inspection.
The site’s patent and staffing totals differ between pages and refer to group-wide activity, so they are not used here as a factory quality score. Product limits remain attached to the named family and document. Confirm the selected configuration in the quotation.
Report an outdated detail · Return to the enquiry checklist ↑