Product details
The same catalog row gives 40% efficiency, 3.5 m required NPSH and 80 kg weight. The table is presented for a liquid density of 1,000 kg/m³. A denser or more viscous process liquid needs a fresh drive and hydraulic assessment rather than an unchanged water-based selection.
The magnetic coupling transmits torque across a static containment boundary. The family description lists fluoroplastic material alternatives including F46, PTFE and PFA. Final wetted construction, bearing materials and temperature limits must be matched to the actual chemical and concentration.
The operating guidance excludes dry running and liquids containing particles or crystals. Optional temperature, dry-run and leakage monitoring should be specified with the controls rather than assumed standard. Confirm adequate suction conditions and an operating range that maintains the internal cooling and lubrication required by the selected magnetic-drive assembly.