PUMP SERIES

Jiangsu Wofulong Pump & Valve Co., Ltd. CQB50-32-160F

Wofulong CQB50-32-160F is a fluoroplastic magnetic-drive selection. At 2,900 r/min, the official table lists 12.5 m³/h flow, 32 m head, a 4 kW motor and 50 / 32 mm inlet and outlet connections.

Request matching quotes
Jiangsu Wofulong Pump & Valve Co., Ltd. CQB50-32-160F — manufacturer product photograph
Official CQB fluoroplastic pump assembly; specifications refer to CQB50-32-160F at 2,900 r/min.

Published specifications

Manufacturer catalog data
Flow range12.5 m³/h
Head range32 m
Motor power4.00 kW
Selected speed2,900 r/min
Inlet / outlet50 / 32 mm
Catalog efficiency40%
Required NPSH3.5 m
Catalog weight80 kg
Table liquid density1,000 kg/m³
FamilyFluoroplastic magnetic-drive chemical pumps
Pumped mediumCompatible clean chemical liquids without particles or crystals
InstallationHorizontal magnetic-drive assembly

Product details

The same catalog row gives 40% efficiency, 3.5 m required NPSH and 80 kg weight. The table is presented for a liquid density of 1,000 kg/m³. A denser or more viscous process liquid needs a fresh drive and hydraulic assessment rather than an unchanged water-based selection.

The magnetic coupling transmits torque across a static containment boundary. The family description lists fluoroplastic material alternatives including F46, PTFE and PFA. Final wetted construction, bearing materials and temperature limits must be matched to the actual chemical and concentration.

The operating guidance excludes dry running and liquids containing particles or crystals. Optional temperature, dry-run and leakage monitoring should be specified with the controls rather than assumed standard. Confirm adequate suction conditions and an operating range that maintains the internal cooling and lubrication required by the selected magnetic-drive assembly.

SELECTION NOTES

Specify the operating duty

Provide clean-liquid chemistry, concentration, density, viscosity, temperature, flow and head, plus available NPSH. Confirm fluoroplastic grade, bearing materials, motor sizing and included monitoring.

Published limits may describe different configurations within a series. Confirm that the required operating conditions are valid together.