PUMP SERIES

Jiangsu Hanna Pump Industry Co., Ltd. CQB65-50-125

Hanna CQB65-50-125 is a stainless magnetic-drive pump selection. The official table lists 25 m³/h flow, 20 m head, a 3 kW motor, 380 V supply and 65 / 50 mm inlet and outlet connections.

Request matching quotes
Jiangsu Hanna Pump Industry Co., Ltd. CQB65-50-125 — manufacturer product photograph
Official stainless CQB assembly; specifications refer to the CQB65-50-125 table row.

Published specifications

Manufacturer catalog data
Flow range25 m³/h
Head range20 m
Motor power3.00 kW
Liquid temperatureUp to 100°C, selected construction
Inlet / outlet65 / 50 mm
Supply voltage380 V
Maximum suction pressure0.2 MPa
Maximum working pressure2.5 MPa
Maximum catalog density1,600 kg/m³
Maximum kinematic viscosity30 cSt
FamilyStainless magnetic-drive centrifugal pumps
Pumped mediumCompatible clean process liquids without hard particles or fibres
InstallationHorizontal magnetic-drive assembly

Product details

The product page specifies suction pressure no higher than 0.2 MPa, maximum working pressure of 2.5 MPa, liquid temperature up to 100°C, density up to 1,600 kg/m³ and kinematic viscosity up to 30 cSt. These conditions require confirmation together for the selected materials and duty; they are not simultaneous guaranteed performance maxima.

The magnetic coupling drives the wetted rotor across a static containment boundary. The manufacturer describes stainless and special-alloy shaft options and several sliding-bearing materials, including graphite and silicon carbide choices. The exact combination must be selected for corrosion, lubrication and thermal conditions.

The stated liquid conditions exclude hard particles and fibres. The bearings depend on the pumped liquid for cooling and lubrication, so dry running is prohibited. Separate CQB-F fluoroplastic and CQB-G high-temperature families are not part of this rating. Confirm the selected duty curve, speed, motor loading and containment arrangement before ordering.

SELECTION NOTES

Specify the operating duty

Provide liquid composition, concentration, density, viscosity, temperature, suction pressure and duty flow and head. Confirm speed, stainless grade, bearings, motor sizing and dry-run protection.

Published limits may describe different configurations within a series. Confirm that the required operating conditions are valid together.