Published specifications
Manufacturer catalog data
Flow range50–4000 m³/h
Head range10–40 m
Motor power400.00 kW
Liquid temperature40 to 70 °C class
FamilyFGD slurry pump
Pumped mediumLimestone / gypsum slurry
InstallationHorizontal FGD
Materials offeredDuplex / high-chrome / rubber
Published standardGB/T 13028
SELECTION NOTES
What to confirm for FGD Desulfurization Series
Chloride, pH and solids concentration control alloy vs rubber.
Published limits may describe different configurations within a series. Confirm that the required operating conditions are valid together.